Viper WatchConfig and Hot Reload

Basic setup

viper.WatchConfig()
viper.OnConfigChange(func(e fsnotify.Event) {
    log.Printf("config changed: %s (op: %s)", e.Name, e.Op)
    // re-read affected values and apply them
})

WatchConfig starts a background goroutine that watches the config file using fsnotify. Call it after ReadInConfig.

The atomic-rename trap

Most editors (vim, neovim, many CI tools) write config files by creating a new file and then renaming it over the old one. This replaces the inode that fsnotify is watching — the watch may not fire, or may fire with Op: RENAME instead of Op: WRITE, or may fire twice.

Test hot reload with direct file writes, not editor saves:

// reliable in tests:
os.WriteFile("config.yaml", newContent, 0644)

// unreliable for testing:
// opening vim and :w — may trigger RENAME instead of WRITE

In production, this is less of an issue if your config management tool (Kubernetes ConfigMap volume mount, Consul Template, etc.) is aware of inode behavior.

Race-safe reload pattern

Config reload happens in a background goroutine. Any shared state updated in OnConfigChange must be synchronized:

type Config struct {
    mu       sync.RWMutex
    LogLevel string `mapstructure:"log_level"`
    MaxConn  int    `mapstructure:"max_conn"`
}

var cfg Config

viper.OnConfigChange(func(e fsnotify.Event) {
    var newCfg Config
    if err := viper.Unmarshal(&newCfg); err != nil {
        log.Printf("error reloading config: %v", err)
        return  // keep old config on error
    }

    cfg.mu.Lock()
    cfg.LogLevel = newCfg.LogLevel
    cfg.MaxConn = newCfg.MaxConn
    cfg.mu.Unlock()

    log.Printf("config reloaded: log_level=%s", newCfg.LogLevel)
})

Reads use appCfg.mu.RLock(). Never read directly from viper in hot paths during reload — the window between OnConfigChange firing and viper updating its internal state is non-deterministic.

Debouncing rapid changes

Some filesystems fire multiple events per save. Debounce to avoid reloading multiple times:

var reloadTimer *time.Timer
var reloadMu sync.Mutex

viper.OnConfigChange(func(e fsnotify.Event) {
    reloadMu.Lock()
    defer reloadMu.Unlock()
    if reloadTimer != nil {
        reloadTimer.Stop()
    }
    reloadTimer = time.AfterFunc(100*time.Millisecond, func() {
        applyNewConfig()
    })
})

Validating config before applying

Always validate reloaded config before applying it — an invalid config mid-reload should keep the previous working config:

viper.OnConfigChange(func(e fsnotify.Event) {
    var candidate Config
    if err := viper.Unmarshal(&candidate); err != nil {
        log.Printf("reload: invalid config, keeping previous: %v", err)
        return
    }
    if err := validate(candidate); err != nil {
        log.Printf("reload: validation failed, keeping previous: %v", err)
        return
    }
    applyConfig(candidate)
})

Stopping the watcher

There is no documented way to stop WatchConfig once started. Design your application so that the watcher's lifetime matches the process lifetime. For testing, create a new viper.New() instance per test — the watcher is per-instance and is garbage-collected with the instance.